Calcium Hardness
Titration Analytical Procedure
-         
Sample
: 10 mL/20 mL/50 mL/100 mL
-         
Add
exactly 2 mL Buffer (460-SO279), Swirl to mix (Colour : Colourless).
-         
Add
Indicator (460-SO280), Swirl to mix
(Colour : Red).
-         
Titration
with Titrant High Range (460-SO274)
until colour change from Red to Violet.
-         
Sample
water used = 10   mL, 
The result (ppm CaCO3)  = Titrant used x 100
Sample water used = 20   mL,  The result (ppm CaCO3)  = Titrant used x 50
Sample water used = 50   mL, 
The result (ppm CaCO3)  = Titrant used x 20
Sample water used = 100
mL,  The result (ppm CaCO3)  = Titrant used x 10